Thermal Care Aquatherm rd temperatureController Chiller

Business and Industrial :: Manufacturing and Metalworking

Thermal Care Aquatherm rd temperatureController Chiller

Start price 499.99 USD
Current price499.99 USD
Start time 04/28/2008
End time 05/08/2008
Bid count 0
See more about Thermal Care Aquatherm rd temperatureController Chiller

Place a bid

 NO RESERVE!!!!! Pulled From Working Service!! Mfg: Thermal Care Model: RA091004Z Year: N/A Features: Aquatherm Model 12RD1hp pump 200-230460V/3/60Approximate weight: 230 lbsApproximate dimensions: 161/2"W x 27"D x 27"Hrd series unit which is a temp controllerThe temperature Range 32dg-F - 260dg-FThe temperature control unit cycles a heater and  cooling valve to maintain precise temperature  control of the To Process water temperature. Your  unit may differ somewhat depending upon the  various options purchased; however, the overall  function of the unit is fundamental to all our  temperature control units.    The pump continuously pumps water from the  mixing tube through the heater tube and out to the  process equipment. The water is pumped through  the process equipment at a high flow rate to ensure  turbulent flow and efficient heat transfer. Once the  water exits the process equipment it returns to the  mixing tube.     A thermocouple is mounted at the exit of the heater  tube to measure the temperature of the To Process  water temperature. This temperature is used by the  microprocessor to determine if temperature  adjustment is required. If the water temperature is  below set point, the heater is energized. Conversely,  the cooling solenoid or modulating valve is opened  whenever the water temperature is above set point.  Opening the cooling solenoid or modulating valve  allows some of the warm water from the process  water circuit to exit through the cooling water out  line. At the same time, cool water is injected into the  process circuit from the cooling water in line. The  replacement of warm water with cool water provides  the cooling that is required. The cooling valve is  cycled by the microprocessor to allow precisely  controlled amounts of cooling water to enter the  system.     A bypass line is provided to protect the pump from  overloading during those times with the process  water circuit is shut off. This prevents the pump from  a deadheading situation and ensures flow through  the pump to keep the pump seal from overheating.     A pressure switch is provided to ensure that there is  sufficient inlet cooling water pressure to allow the  unit to operate without the possibility of steam  flashing. A pressure relief valve is provided to vent  the process loop if the operating pressure becomes  too high.     mixing tubes. The pump volute is constructed of cast  iron. The 3?4 through 2 HP pumps have stainless  steel impellers and pump shafts. The 3 HP through  71?2 HP pumps have an iron impeller with a bronze  wear ring in the pump volute and carbon steel shafts  with a bronze sleeve covering. All pump sizes use a  carbon Ni-Resist mechanical pump seal. All pumps  include a pump seal flush line.     Heater and Mixing Tube   Depending on the options and heater KW capacity  of the unit, there will be either two heater tubes or a  heater tube and a mixing tube. Both the heater and  mixing tubes have been designed to match up to the  pump volute casting. The tubes are constructed of  cast iron and are designed to connect with the pump  volute with two flange seals. Units with 0 KW  through 12 KW heating capacity will include a larger  heater tube and a smaller mixing tube. Units with  heating capacities of 18 KW or 24 KW will have two  larger heater tubes and no mixing tube.     Heater (not available on RB and RBD units)   The heaters are vertical flange mounted with Incoloy  heater element sheathing. All units will use one or  more 9 KW or 12 KW heater elements. The heaters  are energized whenever the microprocessor  determines that heating is required.     Cooling Solenoid or Modulating Valve   The cooling solenoid or modulating valve meters the  cooling water required for proper cooling. The valve  allows warm water to leave the process loop while  letting cooling water to enter the loop. This valve is  also used to vent the process circuit during Vent  and/or Purge sequences.     Pressure Switch   All units are equipped with a pressure switch to  ensure that the unit will not start until the inlet  cooling water pressure exceeds the pressure switch  setting. This safety protects the heater and pump  seal from potential damage caused by lack of water  as well as ensuring that the system pressure is  above the vapor pressure of the water to prevent the  water from flashing to steam. ...Sold AS IS! More info?? email me ross1@charter.net

Related items:
Ky Heavy Tan Braided Leather Split Reins NEW HORSE TACK
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
See also:
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
REINS SPLIT BRIDLE LEATHER LINED LATIGO STITCHED HEAVY
Ky Heavy Brn Braided Leather Split Reins NEW HORSE TACK
HEAVY SPLIT LEATHER WORK APRON w/POCKETS -- VERY RUGGED
Related categories:
Manufacturing Equipment
Metalworking Equipment
Metalworking Tooling, Supplies
Process Equipment
Metals and Alloys
Semiconductor and PCB Equipment
Textile and Apparel Equipment
Welding Equipment and Supplies
Woodworking
Other
Search:

Home
Site map
See also: Dolls and Bears Tickets